Serial Bluetooth Commands

Commands

The valid command starts with byte 0x01 and end with byte 0x04.

Add command

Add command add a device's MAC address to the address list. The valid Add command HEX series is

0x01 + command type (1 byte) + device name (n byte) + 0x03 + device type (1 byte) + MAC address (6 byte) + 0x04

where device name should be the ASCII coding of the device name. By default, the device name should be one of "sensor1", "sensor2", "sensor3", "sensor4", and "sensor5".

Example

If you want to add a remote BLE device with MAC address AA:BB:CC:DD:EE:FF in which the firmware is hktkzyx/environment-sensor-bluetooth, the valid Add command HEX series is 0x 01 05 73 65 6E 73 6F 72 31 03 05 AA BB CC DD EE FF 04 where the first byte 0x05 is the command type of Add command and the second byte 0x05 is the device type. The bytes 0x 73 65 6E 73 6F 72 31 is the ASCII coding of "sensor1".

Remove command

Remove command remove a device from the address list. The valid Remove command HEX series is

0x01 + command type (1 byte) + device name (n byte) + 0x04

where device name should be the ASCII coding of the device name. By default, the device name should be one of "sensor1", "sensor2", "sensor3", "sensor4", and "sensor5".

Example

If you want to remove a remote BLE device naming sensor1 the valid Remove command HEX series is 0x 01 06 73 65 6E 73 6F 72 31 04 where the first byte 0x06 is the command type of Remove command. The bytes 0x 73 65 6E 73 6F 72 31 is the ASCII coding of "sensor1".

Get command

Get command get the device's name, type, and MAC address from the address list. The valid Get command HEX series is

0x01 + command type (1 byte) + device name (n byte) + 0x04

where device name should be the ASCII coding of the device name. By default, the device name should be one of "sensor1", "sensor2", "sensor3", "sensor4", and "sensor5".

Example

If you want to get the info of the remote BLE device naming sensor1 the valid Get command HEX series is 0x 01 07 73 65 6E 73 6F 72 31 04 where the first byte 0x07 is the command type of Remove command. The bytes 0x 73 65 6E 73 6F 72 31 is the ASCII coding of "sensor1".

Clear command

Clear command clear all stored devices' info. The valid Clear command HEX series is

0x01 + command type (1 byte) + 0x04

Example

If you want to clear all stored info the valid Clear command HEX series is 0x 01 08 04 where the first byte 0x08 is the command type of Clear command.

Command type

Command Command type
Add 0x05
Remove 0x06
Get 0x07
Clear 0x08

Device type

The supported remote BLE devices and their device type are as below:

Device Device type
hktkzyx/environment-sensor-bluetooth 0x05